Study guides

Structural Engineering

5 guides for this subject — how to prepare, what to practise, and how to know it has gone in.

A practice question

Choose an answer and it is marked, with the explanation. From Structural Engineering Practice Questions: 10 Worked Checks.

Question 11 mark

A simply supported beam has a 6 m span and carries a single 12 kN point load at midspan. What is the maximum bending moment?

The support reactions are 6 kN each by symmetry. The maximum moment is at midspan: 6 kN × 3 m = 18 kN·m. The strongest distractor is 36 kN·m, which results from using the full 6 m span as the moment arm rather than the 3 m distance from a support to the load.

A spoken answer, marked

An examiner's question, answered out loud and marked criterion by criterion. From Structural Engineering Viva Questions: A Practical Practice Guide.

Oral — The beam with a new openingMarked

Examiner

A client wants a services opening through an existing reinforced-concrete beam. How would you assess the request?

2:313:00Mark answer
78%The beam with a new opening — marked78/100 · Developing · 2:31 spoken of 3:00
Problem definition and information needed19/25

You asked for the opening position and existing drawings, but did not ask whether the beam is part of a continuous frame or identify the applied loads.

ImproveEstablish the structural arrangement, span, supports, loading and proposed opening geometry before discussing a solution.

Structural reasoning and load path21/25

You recognised that the opening interrupts the concrete section and may intersect reinforcement.

ImproveExplain how the opening changes the paths for shear and bending forces, and why its position along the span matters.

Safety and verification19/25

You proposed a survey, but did not clearly say that reinforcement must be located before cutting or that capacity needs checking.

ImproveRequire a suitable reinforcement survey and a verified assessment before any alteration; address temporary works if the intervention could affect stability.

Communication and conclusion19/25

The answer was structured, but it ended without a clear decision or next step.

ImproveConclude that you would not approve cutting until the geometry, reinforcement and capacity had been verified, then state who must review the proposal.

A strong answerI would first confirm the beam’s span, supports, continuity, loading and the proposed opening’s size and position. I would obtain drawings and verify the actual reinforcement and services on site, using an appropriate survey before any cutting. The opening removes part of the section and may interrupt longitudinal reinforcement or links, so I would assess the affected bending, shear and load path rather than rely on a general rule. I would check the altered member against the applicable design basis and consider temporary works and the construction sequence. I would not authorise the opening until the assessment and any strengthening detail had been reviewed and approved.

Start studying structural engineering

Yours are written from your own notes, and the free plan needs no payment details.

Guides

Studying structural engineering? Build your structural engineering board from your own notes — the cards, papers and lectures are written from it. Free plan: 20 cards, a paper, a lecture and a viva to try.

Start on MySummaries

Other subjects